• Geosur
  •  
  •  
  •  

Hydrological station ERORUN, water chemistry in watershed "Rivière des Pluies"

Weekly and monthly physico-chemical water samples of "Rivière des Pluies" watershed, Reunion Island

Simple

Date (Creation)
2016-11-10T08:00:00
Presentation form
Digital table
Purpose
Physico-chemical characterization of the water
Status
On going
Originator
  LGSR - Jean-Lambert Join ( Professor )
15, avenue René Cassin , Saint-Denis , Université de la Réunion , 97744 , France
+262 262 93 86 97
Originator
  IPGP - Éric Gayer ( Professor )
1 rue Jussieu , Paris , IPGP , 75238 , France
+33 1 83 95 74 43
Maintenance and update frequency
Monthly
Originator
  LGSR - Jean-Lambert Join ( Professor )
15, avenue René Cassin , Saint-Denis , Université de la Réunion , 97744 , France
+262 262 93 86 97
Theme
  • Alkalinity
  • Elements
  • Temperature
  • Isotopes
  • pH
  • Conductivity
  • River
  • Water
  • Particle
  • Suspension material
Place
  • Reunion Island
  • Watershed "Rivière des Pluies"
Access constraints
Restricted
Use constraints
Restricted
Spatial representation type
Vector
Denominator
1
Metadata language
English
Character set
UTF8
Topic category
  • Inland waters
  • Environment
Begin date
2016
End date
en cours...
N
S
E
W
thumbnail


Reference system identifier
EPSG:4326
OnLine resource
PlPF1300 ( WWW:LINK-1.0-http--link )
OnLine resource
RvMCan ( null )
OnLine resource
RvPl100 ( null )
OnLine resource
RvPl435 ( null )
OnLine resource
RvQuina ( null )
OnLine resource
TuRPluie ( null )
Hierarchy level
Dataset

Conformance result

Date (Publication)
Statement
The variables concerned correspond to measurements made in the field (T°, Specific conductivity 25° and pH) during water sampling as well as alkalinity measurements made in the laboratory. The selected quality code is divided into 4 categories coded from 1 to 4: Code 1: correct Code 2: suspicious Code 3: bad Code 4: missing. Field measurements: They are carried out in 2016 and 2017 by a WTW conductivity and pH meter and from 2018 by an integrated "Smart-Troll" probe from the manufacturer INSITU). In both cases, the calibration and calibration protocols of the probes are carried out according to the manufacturer's instructions and at least once every 6 months for the conductivity probe and before each output for the pH probe. In this context, the data obtained with these two devices are considered reliable (code 1). Alkalinity measurements: They are performed in the laboratory by titrimetry within 1 to 2 months after sampling. The quality criterion was assessed as the average of two potential sources of error assessed as follows: - Uncertainty about the evolution of the mineralization of the sample evaluated by the variability of the conductivity measured in the field and that measured in the laboratory at the time of the ErCond= Abs(CondTerrain-CondLabo)/Cond terrain in %. - Uncertainty about the titration evaluated by the varibility of the results obtained by different interpretation methods with respect to the Gran method. ErTitr= EcType (HCO3)/Mean (HCO3 calculated by 4 graphical methods). The proposed qualification is based on the average of these two errors f (ErCond+ErTitr)/2<=5% : Code 1 If 5%<(ErCond+ErTitr)/2<=10% : Code 2 If (If (ErCond + ErTitr)not defined: Code 4
File identifier
dc0a5fa8-1d05-4656-969b-cb3f670023fe XML
Metadata language
English
Character set
UTF8
Date stamp
2021-10-28T12:18:10
Metadata standard name
ISO 19115:2003/19139
Metadata standard version
1.0
Custodian
  UMS3365 - Rémy Decoupes ( IT Manager )
15, avenue René Cassin , Saint-Denis , Université de la Réunion , 97744 , France
+262 262 93 82 28
Processor
  UMS3365 - Pierre Stamenoff ( Scientific instrumentation & experimental techniques technician )
15, avenue René Cassin , Saint-Denis , Université de la Réunion , 97744 , France
+262 692 20 30 44
Processor
  LGSR - Geneviève Lebeau ( Laboratory technician )
15, avenue René Cassin , Saint-Denis , Université de la Réunion , 97744 , France
+262 262 93 86 77
Processor
  UMS3365 - Yoan Benoit ( Scientific instrumentation & experimental techniques technician )
15, avenue René Cassin , Saint-Denis , Université de la Réunion , 97744 , France
+262 692 20 30 44
 
 

Overviews

overview overview

Spatial extent

N
S
E
W
thumbnail


Keywords

Alkalinity Conductivity Elements Isotopes Particle River Suspension material Temperature Water pH

Provided by

logo

Share on social sites

Access to the portal
Read here the full details and access to the data.

Associated resources

Not available


  •  
  •  
  •