• GEOSUR
  •   Search
  •   Map
  •  Sign in

Hydrological station ERORUN, water chemistry in watershed "Rivière des Pluies"
Station d'observation ERORUN, chimie de l'eau, bassin versant de la Rivières des Pluies, Ile de la Réunion

  • English
  • Français
  • All

Weekly and monthly physico-chemical water samples of "Rivière des Pluies" watershed, Reunion Island

Prélèvements physico-chimiques hebdomadaire et mensuel des eaux du bassin versant de la Rivières des Pluies, île de la Réunion

Simple

Date (Création)
Date (Creation)
2016-11-10T08:00:00
Forme de la présentation
Presentation form
Table numérique
Digital table
Purpose
But

Physico-chemical characterization of the water

Caractérisation physico-chimique de l'eau

Etat
Status
Mise à jour continue
On going
Point of contact
Organisation name Individual name Electronic mail address Role

LGSR

LGSR

Jean-Lambert Join

Jean-Lambert Join

join@univ-reunion.fr

join@univ-reunion.fr

A l’origine de
Originator

IPGP

IPGP

Éric Gayer

Jérôme Gaillardet

egayer@ipgp.fr

gaillardet@ipgp.fr

A l’origine de
Originator
Fréquence de mise à jour
Maintenance and update frequency
Mensuelle
Monthly
Metadata author
Organisation name Individual name Electronic mail address Role

LGSR

LGSR

Jean-Lambert Join

Jean-Lambert Join

join@univ-reunion.fr

join@univ-reunion.fr

A l’origine de
Originator
Thème
Theme
  • Alkalinity

    Alcalinité

  • Elements

    Elements

  • Temperature

    Temperature

  • Isotopes

    Isotopes

  • pH

    pH

  • Conductivity

  • River

    Rivières

  • Water

    Eau

  • Particle

    Particule

  • Suspension material

    Matériel en suspension

Localisation
Place
  • Reunion Island

    Ile de la Réunion

  • Watershed "Rivière des Pluies"

    Bassin versant de la Rivière des Pluies

OSU-Réunion
  • OZC-R
Contraintes d'accès
Access constraints
Restreint
Restricted
Contraintes d'utilisation
Use constraints
Restreint
Restricted
Type de représentation spatiale
Spatial representation type
Vecteur
Vector
Dénominateur de l'échelle
Denominator
1
Langue de la ressource
Language
English
Encodage des caractères
Character set
Utf8
UTF8
Catégorie ISO
Topic category
  • Eaux intérieures, Hydrographie
    Inland waters
  • Environnement
    Environment
Begin date
2016
End date
en cours...
N
S
E
W
thumbnail




Nom du système de référence
Reference system identifier
EPSG:4326
Ressource en ligne
OnLine resource
PlPF1300
RvMCan
RvPl100
RvPl435
RvQuina
TuRPluie
Niveau
Hierarchy level
Jeu de données
Dataset

Résultat de conformité
Conformance result

Date (Publication)
Date (Publication)
Statement

The variables concerned correspond to measurements made in the field (T°, Specific conductivity 25° and pH) during water sampling as well as alkalinity measurements made in the laboratory. The selected quality code is divided into 4 categories coded from 1 to 4: Code 1: correct Code 2: suspicious Code 3: bad Code 4: missing. Field measurements: They are carried out in 2016 and 2017 by a WTW conductivity and pH meter and from 2018 by an integrated "Smart-Troll" probe from the manufacturer INSITU). In both cases, the calibration and calibration protocols of the probes are carried out according to the manufacturer's instructions and at least once every 6 months for the conductivity probe and before each output for the pH probe. In this context, the data obtained with these two devices are considered reliable (code 1). Alkalinity measurements: They are performed in the laboratory by titrimetry within 1 to 2 months after sampling. The quality criterion was assessed as the average of two potential sources of error assessed as follows: - Uncertainty about the evolution of the mineralization of the sample evaluated by the variability of the conductivity measured in the field and that measured in the laboratory at the time of the ErCond= Abs(CondTerrain-CondLabo)/Cond terrain in %. - Uncertainty about the titration evaluated by the varibility of the results obtained by different interpretation methods with respect to the Gran method. ErTitr= EcType (HCO3)/Mean (HCO3 calculated by 4 graphical methods). The proposed qualification is based on the average of these two errors f (ErCond+ErTitr)/2<=5% : Code 1 If 5%<(ErCond+ErTitr)/2<=10% : Code 2 If (If (ErCond + ErTitr)not defined: Code 4

Metadata

Identifiant de la fiche
File identifier
dc0a5fa8-1d05-4656-969b-cb3f670023fe XML
Langue
Metadata language
English
Jeu de caractères
Character set
Utf8
UTF8
Date des métadonnées
Date stamp
2026-06-16T05:47:58.293625Z
Metadata standard name

ISO 19115:2003/19139

Metadata standard version

1.0

Metadata author
Organisation name Individual name Electronic mail address Role

UMS3365

UMS3365

Rémy Decoupes

Rémy Decoupes

remy.decoupes@univ-reunion.fr

remy.decoupes@univ-reunion.fr

Gestionnaire
Custodian

UMS3365

UMS3365

Pierre Stamenoff

Pierre Stamenoff

pierre.stamenoff@univ-reunion.fr

pierre.stamenoff@univ-reunion.fr

Exécutant
Processor

LGSR

LGSR

Geneviève Lebeau

Geneviève Lebeau

genevieve.lebeau@univ-reunion.fr

genevieve.lebeau@univ-reunion.fr

Exécutant
Processor

UMS3365

Yoan Benoit

yoan.benoit@univ-reunion.fr

Exécutant
Processor
Other language
Language Character encoding
Français
French
Anglais
English
Utf8
UTF8
 
 

Citation proposal

Jean-Lambert Join Jean-Lambert Join (LGSRLGSR), & Éric Gayer Jérôme Gaillardet (IPGPIPGP).

Hydrological station ERORUN, water chemistry in watershed "Rivière des Pluies"
Station d'observation ERORUN, chimie de l'eau, bassin versant de la Rivières des Pluies, Ile de la Réunion
[Jeu de données].

https://geosur.osureunion.fr/geonetwork/srv/api/records/dc0a5fa8-1d05-4656-969b-cb3f670023fe

Overviews

overview
overview

Spatial extent

thumbnail

Keywords

Alkalinity
Alcalinité
Conductivity
Elements
Elements
Isotopes
Isotopes
Particle
Particule
River
Rivières
Suspension material
Matériel en suspension
Temperature
Temperature
Water
Eau
pH
pH

OSU-Réunion

OZC-R


Provided by

logo
Access to the catalogue
Read here the full details and access to the data.




© OSU-Réunion — Geospatial Metadata Catalogue GEOSUR Powered by GeoNetwork 4.4.5