Hydrological station ERORUN, water chemistry in watershed "Rivière des Pluies"
Weekly and monthly physico-chemical water samples of "Rivière des Pluies" watershed, Reunion Island
Simple
- Date (Creation)
- 2016-11-10T08:00:00
- Presentation form
- Digital table
- Purpose
-
Physico-chemical characterization of the water
- Status
- On going
- Point of contact
-
Organisation name Individual name Electronic mail address Role LGSR
Jean-Lambert Join
Originator IPGP
Éric Gayer
Originator
- Maintenance and update frequency
- Monthly
- Metadata author
-
Organisation name Individual name Electronic mail address Role LGSR
Jean-Lambert Join
Originator
- Theme
-
-
Alkalinity
-
Elements
-
Temperature
-
Isotopes
-
pH
-
Conductivity
-
River
-
Water
-
Particle
-
Suspension material
-
- Place
-
-
Reunion Island
-
Watershed "Rivière des Pluies"
-
- Access constraints
- Restricted
- Use constraints
- Restricted
- Spatial representation type
- Vector
- Denominator
- 1
- Language
- English
- Character set
- UTF8
- Topic category
-
- Inland waters
- Environment
- Begin date
- 2016
- End date
- en cours...
- Reference system identifier
- EPSG:4326
- OnLine resource
- Hierarchy level
- Dataset
Conformance result
- Date (Publication)
- Statement
-
The variables concerned correspond to measurements made in the field (T°, Specific conductivity 25° and pH) during water sampling as well as alkalinity measurements made in the laboratory. The selected quality code is divided into 4 categories coded from 1 to 4: Code 1: correct Code 2: suspicious Code 3: bad Code 4: missing. Field measurements: They are carried out in 2016 and 2017 by a WTW conductivity and pH meter and from 2018 by an integrated "Smart-Troll" probe from the manufacturer INSITU). In both cases, the calibration and calibration protocols of the probes are carried out according to the manufacturer's instructions and at least once every 6 months for the conductivity probe and before each output for the pH probe. In this context, the data obtained with these two devices are considered reliable (code 1). Alkalinity measurements: They are performed in the laboratory by titrimetry within 1 to 2 months after sampling. The quality criterion was assessed as the average of two potential sources of error assessed as follows: - Uncertainty about the evolution of the mineralization of the sample evaluated by the variability of the conductivity measured in the field and that measured in the laboratory at the time of the ErCond= Abs(CondTerrain-CondLabo)/Cond terrain in %. - Uncertainty about the titration evaluated by the varibility of the results obtained by different interpretation methods with respect to the Gran method. ErTitr= EcType (HCO3)/Mean (HCO3 calculated by 4 graphical methods). The proposed qualification is based on the average of these two errors f (ErCond+ErTitr)/2<=5% : Code 1 If 5%<(ErCond+ErTitr)/2<=10% : Code 2 If (If (ErCond + ErTitr)not defined: Code 4
Metadata
- File identifier
- dc0a5fa8-1d05-4656-969b-cb3f670023fe XML
- Metadata language
- English
- Character set
- UTF8
- Date stamp
- 2026-06-16T05:47:58.293625Z
- Metadata standard name
-
ISO 19115:2003/19139
- Metadata standard version
-
1.0
- Metadata author
-
Organisation name Individual name Electronic mail address Role UMS3365
Rémy Decoupes
Custodian UMS3365
Pierre Stamenoff
Processor LGSR
Geneviève Lebeau
Processor UMS3365
Yoan Benoit
Processor
- Other language
-
Language Character encoding French English UTF8
Citation proposal
Jean-Lambert Join (LGSR), & Éric Gayer (IPGP).
Hydrological station ERORUN, water chemistry in watershed "Rivière des Pluies" [Jeu de données].
https://geosur.osureunion.fr/geonetwork/srv/api/records/dc0a5fa8-1d05-4656-969b-cb3f670023fe