Station d'observation ERORUN, chimie de l'eau, bassin versant de la Rivières des Pluies, Ile de la Réunion
Prélèvements physico-chimiques hebdomadaire et mensuel des eaux du bassin versant de la Rivières des Pluies, île de la Réunion
Simple
- Date (Création)
- 2016-11-10T08:00:00
- Forme de la présentation
- Table numérique
- But
-
Caractérisation physico-chimique de l'eau
- Etat
- Mise à jour continue
- Contact pour la ressource
-
Nom de l'organisation Nom de la personne Adresse e-mail Rôle LGSR
Jean-Lambert Join
A l’origine de IPGP
Jérôme Gaillardet
A l’origine de
- Fréquence de mise à jour
- Mensuelle
- Contact
-
Nom de l'organisation Nom de la personne Adresse e-mail Rôle LGSR
Jean-Lambert Join
A l’origine de
- Thème
-
-
Alcalinité
-
Elements
-
Temperature
-
Isotopes
-
pH
-
Conductivity
-
Rivières
-
Eau
-
Particule
-
Matériel en suspension
-
- Localisation
-
-
Ile de la Réunion
-
Bassin versant de la Rivière des Pluies
-
- Contraintes d'accès
- Restreint
- Contraintes d'utilisation
- Restreint
- Type de représentation spatiale
- Vecteur
- Dénominateur de l'échelle
- 1
- Langue de la ressource
- English
- Encodage des caractères
- Utf8
- Catégorie ISO
-
- Eaux intérieures, Hydrographie
- Environnement
- Date de début
- 2016
- Date de fin
- en cours...
- Nom du système de référence
- EPSG:4326
- Ressource en ligne
- Niveau
- Jeu de données
Résultat de conformité
- Date (Publication)
- Généralités sur la provenance
-
The variables concerned correspond to measurements made in the field (T°, Specific conductivity 25° and pH) during water sampling as well as alkalinity measurements made in the laboratory. The selected quality code is divided into 4 categories coded from 1 to 4: Code 1: correct Code 2: suspicious Code 3: bad Code 4: missing. Field measurements: They are carried out in 2016 and 2017 by a WTW conductivity and pH meter and from 2018 by an integrated "Smart-Troll" probe from the manufacturer INSITU). In both cases, the calibration and calibration protocols of the probes are carried out according to the manufacturer's instructions and at least once every 6 months for the conductivity probe and before each output for the pH probe. In this context, the data obtained with these two devices are considered reliable (code 1). Alkalinity measurements: They are performed in the laboratory by titrimetry within 1 to 2 months after sampling. The quality criterion was assessed as the average of two potential sources of error assessed as follows: - Uncertainty about the evolution of the mineralization of the sample evaluated by the variability of the conductivity measured in the field and that measured in the laboratory at the time of the ErCond= Abs(CondTerrain-CondLabo)/Cond terrain in %. - Uncertainty about the titration evaluated by the varibility of the results obtained by different interpretation methods with respect to the Gran method. ErTitr= EcType (HCO3)/Mean (HCO3 calculated by 4 graphical methods). The proposed qualification is based on the average of these two errors f (ErCond+ErTitr)/2<=5% : Code 1 If 5%<(ErCond+ErTitr)/2<=10% : Code 2 If (If (ErCond + ErTitr)not defined: Code 4
Métadonnées
- Identifiant de la fiche
- dc0a5fa8-1d05-4656-969b-cb3f670023fe XML
- Langue
- English
- Jeu de caractères
- Utf8
- Date des métadonnées
- 2026-06-16T05:47:58.293625Z
- Nom du standard de métadonnées
-
ISO 19115:2003/19139
- Version du standard de métadonnées
-
1.0
- Contact
-
Nom de l'organisation Nom de la personne Adresse e-mail Rôle UMS3365
Rémy Decoupes
Gestionnaire UMS3365
Pierre Stamenoff
Exécutant LGSR
Geneviève Lebeau
Exécutant UMS3365
Yoan Benoit
Exécutant
- Autre langue
-
LanguageCode CharacterEncoding Français Anglais Utf8
Proposition de citation
Jean-Lambert Join (LGSR), & Jérôme Gaillardet (IPGP).
Station d'observation ERORUN, chimie de l'eau, bassin versant de la Rivières des Pluies, Ile de la Réunion [Jeu de données].
https://geosur.osureunion.fr/geonetwork/srv/api/records/dc0a5fa8-1d05-4656-969b-cb3f670023fe